2000.35.016

DIN Rail Mount Temperature Data Logger
  • Features
    • Isolated
    • Thermocouple and RTD Input
    • Loop Powered
    • Near Field Configuration
    • Data Logger



DIN Rail Mount Temperature Data Logger

Head mount RTD data logger infographics

The 2000.35.016 is a DIN rail mount temperature transmitter that can accept signals from thermocouple and RTD's. The 2000.35.016 input and output are isolated from each other. It also has a data logger with the ability to store a temperature measurement from once a second up to every one hour. The datalogger can be set up with a PC, Android phone and with the use of a bluetooth programmer, an iPhone.
The head mounted RTD temperature transmitter accepts inputs from Pt100, Ni100 and Pt1000 2, 3 and 4 Wire RTD's and provides a 4-20mA output from 6 - 32 Vdc.


2000.35.016 Specifications

Power Supply 6 - 32 Vdc.
Input type mV, K, S, R, J, T, N, B, E Thermocouples.
Input type RTD Pt100, Ni100. 2 Wire, 3 Wire and 4 Wire.
Operative Temperature -40°F +185°F 40°C +85°C
Humidity (non condensing) 30-90%.
Housing Nylon PA66.
Dimensions W x D x H 0.7 x 2.5 x 3.5inch, 18 x 64 x 90mm.
Weight 1 oz 30 g.
EMC For industrial environments.
Immunity EN 61000-6-2.
Emission EN 61000-6-4.
Configuration NFC with PC Configurable, MyPixsys App with Android or iPhone with the blue tooth programmer.

2 Wire RTD Wiring Connections

3 Wire Connection
Power Supply 6-32V DC
Postive Terminal 5
Negative Terminal 7
Input 2 wire
White wire Terminal 1
Red wire Terminal 4

2 Wire RTD Input

DIN Rail 2 Wire RTD data logger wiring diagram

3 Wire RTD Wiring Connections

3 Wire Connection
Power Supply 6-32V DC
Postive Terminal 5
Negative Terminal 7
Input 3 wire
White wire Terminal 1
Red wire Terminal 3
Red wire Terminal 4

3 Wire RTD Input

DIN Rail 3 Wire RTD data logger wiring diagram

4 Wire Wiring Connections

4 Wire Connection
Power Supply 6-32V DC
Postive Terminal 5
Negative Terminal 7
Input 4 wire
White wire Terminal 1
Red wire Terminal 3
White wire Terminal 2
Red wire Terminal 4

4 Wire RTD Input

DIN Rail 4 Wire RTD data logger wiring diagram

Thermocouple Wiring Connections

ThermocoupleConnection
Power Supply 6-32V DC
Postive Terminal 5
Negative Terminal 7
Thermocouple mV
Negative Terminal 1
Positive Terminal 2

Thermocouple Input

Din rail thermocoulpe data logger wiring diagram


Pixsys Electronics USA

Pixsys Electronics products are sold and supported by Datexel LLC in the USA.

Contact

☏ 561 779 5660

✉ Info@pixsys.com